NS18
Online Infrared Sensors

■ Temperature range : -20℃ ~ 500℃
■ Optical resolution up to 15:1
■ 150 ms response time
■ 4~20mA , 0~5V , Type K or J output
■ RS485 , TTL digital interface
■ Power Supply 24VDC
■ Rugged IP 66 stainless steel housing
■ Standard 2m cable

ce_rohs_logo.png
NS18

General Specifications

 

Environmental Rating                                                       IP 66

Ambient Temperature                                                      0ºC to 70ºC

Storage Temperature                                                        -20ºC to 80ºC

Relative Humidity                                                              10 to 95%, non-condensing

Cable Temperature                                                           -20ºC to 80ºC

Weight                                                                                 170g ±5%

Electrical Specifications

 

Analog Output                                                                    0~5V / 4-20mA / Type K or J

Digital Output                                                                     RS485, TTL (4~20mA 2-wire)

Power Supply                                                                      24 VDC ± 20%

Cable Length                                                                       2 m (standard), 5m or 10m

Measurement Specifications

 

Temperature Range                                                           -20ºC ~ 500ºC

                                                                                            

Spectral Response                                                             8 ~ 14 μm

 

Optics Resolution

(90% energy)                                                                       15 : 1

 

Accuracy*¹                                                                          

                                                                                              (V/A) ±1.5% of reading or ±1.5(℃)

                                                                                              whichever is greater ¹⁾²⁾³⁾

                                                                                              ( TC ) ±1.5% of reading or ±3(℃)

                                                                                              whichever is greater ¹⁾²⁾⁴⁾

 

Repeatability*¹                                                            

                                                                                              (V/A) ±0.5% of reading or ±1(℃)

                                                                                              whichever is greater ²⁾

                                                                                              (TC ) ±0.5% of reading or ±2(℃)

                                                                                              whichever is greater ²⁾

Temperature Resolution                                                   0.1ºC

Response Time (95% signal)                                            150 ms

Emissivity (adjustable)                                                 0.100 ~ 1.100 (PC software adjustable)

Transmissivity                                                                     0.100 ~ 1.000 (PC software adjustable)

¹⁾ At 23ºC ± 5ºC, emissivity = 0.95

²⁾ object temperature > 0ºC

³⁾ ±3ºC (object temperature ≤ 0ºC)

⁴⁾ ±3.5ºC (object temperature ≤ 0ºC)