top of page
  • White Facebook Icon
  • 49419-sina-social-logo-of-an-eye-icon-vector-icon-vector-eps
  • White YouTube Icon
  • Mail-Icon-White-on-Black

NS10LT
Online Infrared Sensors

■ Temperature range : 0℃ ~ 500℃
■ Optical resolution up to 15:1
■ 150 ms response time
■ 0~5V, Type K or J output
■ Built-In RS485 MODBUS RTU interface
■ Power Supply 24VDC
■ Rugged IP 65 stainless steel housing
■ Standard 2m cable

ce_rohs_logo.png
NS10_01
NS10_02
NS10_03
NS10_04

General Specifications

 

Environmental Rating                                                       IP 65

Ambient Temperature                                                      0ºC to 70ºC

Storage Temperature                                                        -20ºC to 80ºC

Relative Humidity                                                              10 to 95%, non-condensing

Cable Temperature                                                           -20ºC to 80ºC

Weight                                                                                 150g (2m cable)

Electrical Specifications

 

Analog Output                                                                    0~5V , Type K or J

Digital Output                                                                     RS485 (2-wire)

Protocol                                                                               Autonomous agreement /  Modbus RTU

Maximum Loop Resistance                                              10 Ω

Power Supply                                                                      24 VDC ± 20%

Current Draw                                                                      max. 50 mA

Cable Length                                                                       2 m (standard), 5m or 10m

Measurement Specifications

 

Temperature Range                                                           0ºC ~ 500ºC (32ºF to 932ºF)

 

Spectral Response                                                             8 ~ 14 μm

Optics Resolution                                                              15 : 1

(90% energy)                                                                       

 

Accuracy*¹                                                                          ±1% of reading or ±1.5ºC, whichever is greater

 

Repeatability*¹                                                            ±0.5% of reading or ±1ºC, whichever is

                                                                                              greater

Temperature Resolution                                                   0.1ºC

Response Time (95% signal)                                            150 ms

Emissivity (adjustable)                                                 0.100 ~ 1.000 (PC software adjustable)

                                                                                              0.950 Fixed (Type K)

Signal processing                                                               peak hold, valley hold, average

                                                                                              ( 0~5V , Type J )

*¹ At 23ºC ± 5ºC, emissivity = 0.95

bottom of page